The MAT3 DALI module, equipped with sophisticated microprocessor module, is pre-programmed to carry out testing automatically. Connecting MAT3 module to emergency kit predisposed, obtain a localized system which information, on the functionality, are provided by three-colour led, positioned on the lamp.
MAT3 The module is designed to be connected via "two wire DALI BUS" (1) to a central control DALI. The result is a centralized system for full supervision of the whole system.
Complying with IEC 62386-202
Function test
Every 7 days it carry out a short test (about 30 seconds) on the function for lamp.
Duration test
Every 12 weeks it carry out a test (1 or 3 hours) to check battery capacity.
Routine test
Routine test starts when kit is supplied and resetted itself removing mains supply and battery.
Color Led | Status |
Yellow Blinking | Battery charging: – for 24 hours after installation, after at least 10’ black-out, or after full discarge |
Green Blinking | Test in progress: – single blink, lamp test – double blink, battery test |
Green Permanent | All ok |
Red Blinking | Test in progress: – Single blink, lamp fault – Double blink, battery fault |
Off | No mains |