Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. current (at 230 V, 50 Hz, full load) (1) (2) | 96 – 192 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 35 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) (2) | < 500 µA |
Typ. efficiency (at 230 V, 50 Hz, full load) (2) | 87 % |
λ (at 230 V, 50 Hz, full load) (1) | > 0.96C |
Typ. power input on stand-by (3) | < 0.25 W |
Typ. input current in no-load operation | 22 mA |
Typ. input power in no-load operation | < 0.5 W |
In-rush current (peak / duration) | 26.4 A / 224 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 10 % |
Time to light (at 230 V, 50 Hz, full load) (1) | < 0.6 s |
Time to light (DC mode) | < 0.4 s |
Switchover time (AC/DC) | < 0.2 s |
Turn off time (at 230 V, 50 Hz, full load) | < 20 ms |
Output current tolerance (1) (4) | ± 3 % |
Max. output current peak (non-repetitive) | ≤ output current + 20 % |
Output LF current ripple (< 120 Hz) | ± 2 % |
Max. output voltage (U-OUT) | 60 V |
Dimming range | 1 – 100 % |
Colour tuning range | 2,700 – 6,500 K |
Mains surge capability (between L - N) | 1 kV |
Mains surge capability (between L/N - PE) | 2 kV |
Surge voltage at output side (against PE) | < 500 V |
Type of protection | IP20 |
Dimensions L x W x H | 215 x 70 x 31 mm |