EXCITE indoor IP20 series
LCU 180W 24V SR TOP
| Technical data | |
|---|---|
| Rated supply voltage | 120 – 277 V |
| AC voltage range | 108 – 305 V |
| DC voltage range | 176 – 288 V |
| Rated current (at 120 V 60 Hz, full load) | 1.67 A |
| Rated current (at 230 V, 50 Hz, full load) | 0.92 A |
| Rated current (at 277 V 60 Hz, full load) | 0.73 A |
| Mains frequency | 0 / 50 / 60 Hz |
| Efficiency (at 120 V 60 Hz, full load) | > 91 % |
| Efficiency (at 230 V, 50 Hz, full load) | > 90 % |
| Efficiency (at 277 V 60 Hz, full load) | > 93 % |
| λ (at 120 V, 60 Hz, full load) | 0.99 |
| λ (at 230 V, 50 Hz, full load) | 0.95 |
| λ (at 277 V, 60 Hz, full load) | 0.97 |
| Output voltage tolerance | -0 ... +5 % |
| Output power (ta ≤ 50 °C) | 180 W |
| Output power (ta > 50 °C) | 126 W |
| Output power range | 18 – 180 W |
| Turn on time (output) | ≤ 0.5 s |
| Turn off time (output) | ≤ 1 s |
| Hold on time at power failure (output) | 10 ms |
| Mains surge capability (between L - N) | 1 kV |
| Mains surge capability (between L/N - PE) | 1 kV |
| Surge voltage at output side (against PE) | < 500 V |
| Ambient temperature ta | -25 ... +60 °C |
| Ambient temperature ta (at life-time 50,000 h) (1) | -25 ... +45 °C |
| Storage temperature ts | -40 ... +85 °C |
| Dimensions L x W x H | 280 x 64 x 31 mm |
| Hole spacing D | 253 mm |
| Artikel | Artikelcode |
|---|---|
| LCU 180W 24V TOP SR | LCU 180W 24V TOP SR |