Rated supply voltage | 220 – 240 V |
AC voltage range | 198 – 264 V |
inputDIM voltage range | 170 – 250V |
DC voltage range | 176 – 280 V |
Mains frequency | 0 / 50 / 60 Hz |
Overvoltage protection | 320 V AC, 48 h |
Typ. current (at 230 V, 50 Hz, full load) (1) (2) | 169 – 647 mA |
Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 48 – 117 mA |
Leakage current (at 230 V, 50 Hz, full load) (1) (2) | < 450 µA |
Max. input power | 147 W |
Typ. efficiency (at 230 V, 50 Hz, full load) (2) (3) | 93 % |
λ (at 230 V, 50 Hz, full load) (1) | 0.98C |
Typ. power input on stand-by (4) | < 0.16 W |
In-rush current (peak / duration) | 65 A / 268 µs |
THD (at 230 V, 50 Hz, full load) (1) | < 8 % |
Starting time (at 230 V, 50 Hz, full load) (1) | < 750 ms |
Starting time (DC mode) | < 800 ms |
Switchover time (AC/DC) | < 300 ms |
Turn off time (at 230 V, 50 Hz, full load) | < 500 ms |
Output current tolerance (1) (5) | ± 3 % |
Max. output current peak (non-repetitive) | ≤ output current + 15 % |
Output LF current ripple (< 120 Hz) | ± 5 % |
Max. output voltage (HV) | 280 V |
Max. output voltage (LV) | 180 V |
Dimming range | 5 – 100 % (min. 10 mA) |
Mains surge capability (between L - N) (6) | 6 kV / 3 kA |
Mains surge capability (between L/N - PE) | 6 kV |
Mains surge capability up to (between L/N - PE) without DALI connection | 10 kV |
Burst protection (7) | 6 kV |
Surge voltage at output side (against PE) | < 1 kV |
Type of protection | IP20 |
Dimensions L x W x H | 150 x 90 x 37.5 mm |