PREMIUM series non-SELV

| Technical data | |
|---|---|
| Rated supply voltage | 220 – 240 V |
| AC voltage range | 198 – 264 V |
| DC voltage range | 176 – 280 V |
| Mains frequency | 0 / 50 / 60 Hz |
| Overvoltage protection | 320 V AC, 48 h |
| Typ. rated current (at 230 V, 50 Hz, full load) (1) (2) | 681 mA |
| Typ. current (220 V, 0 Hz, full load, 15 % dimming level) (2) | 119 mA |
| Leakage current (at 230 V, 50 Hz, full load) (1) (2) | < 250 µA |
| Max. input power | 157.1 W |
| Typ. efficiency (at 230 V, 50 Hz, full load) (2) | 95 % |
| λ (at 230 V, 50 Hz, full load) | 0.98C |
| Typ. power input on stand-by (3) | < 0.25 W |
| Typ. input current in no-load operation | 78 mA |
| Typ. input power in no-load operation | 0.54 W |
| In-rush current (peak / duration) | 17.7 A / 162 µs |
| THD (at 230 V, 50 Hz, full load) (1) | < 4 % |
| Time to light (at 230 V, 50 Hz, full load) (1) | < 0.6 s |
| Time to light (DC mode) | < 0.4 s |
| Switchover time (AC/DC) | < 0.4 s |
| Turn off time (at 230 V, 50 Hz, full load) | < 2.4 ms |
| Output current tolerance (1) (4) | ± 3 % |
| Max. output current peak (non-repetitive) | ≤ output current + 30 % |
| Output LF current ripple (< 120 Hz) | ± 2 % |
| Max. output voltage (U-OUT) | 350 V |
| Dimming range | 1 – 100 % |
| Mains surge capability (between L - N) | 4 kV |
| Mains surge capability (between L/N - PE) | 4 kV |
| Surge voltage at output side (against PE) | 4 kV |
| Dimensions L x W x H | 360 x 30 x 28 mm |
| Artikel | Artikelcode |
|---|---|
| LCI 150/325-1050/300 o4a sl PRE | 28002053 |